Overall Trends
Total, fatal, and serious accidents in the selected range.
Search investigations, review source evidence, monitor watched reports, and trace long-term patterns from one calm, data-first workspace.
Fast key and full-text search with live filters, watches, and precise metadata.
Use quotes for exact phrase matches (for example "fuel selector valve").
Track fatal and non-fatal accident patterns across Part 91, Part 135, and Part 121 operations.
Major cases, deep-report coverage, and investigation media across decades of NTSB history.
Move quickly by aircraft, airport, operator, and time with indexes built for research, not wandering.
NTSB Reports is an independent research and search tool for public aviation accident and incident records. It brings NTSB aviation reports, structured fields, docket files, extracted figures, photos, videos, and update history into one searchable interface.
The goal is practical safety education: make it faster to find relevant investigations, compare similar events, review factual records, and understand the evidence behind probable-cause and preliminary reports.
The investigative work and source records belong to the National Transportation Safety Board and the published investigation record. This site is not affiliated with or endorsed by the NTSB.
Slatington, PA
AS THE HOMEBUILT ACFT WAS CLIMBING THRU ABOUT 300 FT AGL DURING INITIAL CLIMB AFTER TAKEOFF, THE ENG LOST POWER. THE PLT WAS ABLE TO RESTART THE ENG (ONCE), BUT AS HE TURNED THE ACFT BACK TOWARD THE ARPT, THE ENG LOST POWER AGAIN. DURING AN EMERG LANDING, THE ACFT STRUCK TREES IN A WOODED AREA ABOUT 1/4 MI FROM THE ARPT. NO PREIMPACT PART FAILURE OR MALFUNCTION OF THE ACFT OR ENG WAS FOUND. THE PLT HAD RECENTLY PURCHASED THE ACFT & WAS USING FUEL FROM THE WING TANKS FOR THE 1ST TIME WHEN THE ENG LOST POWER. HE REPORTED THAT THE WING TANKS WERE FULL OF AUTO FUEL, WHICH THE PREVIOUS OWNER HAD USED. THE PREVIOUS OWNER HAD NOT FLOWN THE ACFT FOR MORE THAN A YEAR. IMPACT DAMAGE COMPROMISED THE FUEL SYSTEM, PRECLUDING ANY ASSESSMENT OF THE FUEL CONDITIONS.
AS THE HOMEBUILT ACFT WAS CLIMBING THRU ABOUT 300 FT AGL DURING INITIAL CLIMB AFTER TAKEOFF, THE ENG LOST POWER. THE PLT WAS ABLE TO RESTART THE ENG (ONCE), BUT AS HE TURNED THE ACFT BACK TOWARD THE ARPT, THE ENG LOST POWER AGAIN. DURING AN EMERG LANDING, THE ACFT STRUCK TREES IN A WOODED AREA ABOUT 1/4 MI FROM THE ARPT. NO PREIMPACT PART FAILURE OR MALFUNCTION OF THE ACFT OR ENG WAS FOUND. THE PLT HAD RECENTLY PURCHASED THE ACFT & WAS USING FUEL FROM THE WING TANKS FOR THE 1ST TIME WHEN THE ENG LOST POWER. HE REPORTED THAT THE WING TANKS WERE FULL OF AUTO FUEL, WHICH THE PREVIOUS OWNER HAD USED. THE PREVIOUS OWNER HAD NOT FLOWN THE ACFT FOR MORE THAN A YEAR. IMPACT DAMAGE COMPROMISED THE FUEL SYSTEM, PRECLUDING ANY ASSESSMENT OF THE FUEL CONDITIONS.