Overall Trends
Total, fatal, and serious accidents in the selected range.
Search investigations, review source evidence, monitor watched reports, and trace long-term patterns from one calm, data-first workspace.
Fast key and full-text search with live filters, watches, and precise metadata.
Use quotes for exact phrase matches (for example "fuel selector valve").
Track fatal and non-fatal accident patterns across Part 91, Part 135, and Part 121 operations.
Major cases, deep-report coverage, and investigation media across decades of NTSB history.
Move quickly by aircraft, airport, operator, and time with indexes built for research, not wandering.
NTSB Reports is an independent research and search tool for public aviation accident and incident records. It brings NTSB aviation reports, structured fields, docket files, extracted figures, photos, videos, and update history into one searchable interface.
The goal is practical safety education: make it faster to find relevant investigations, compare similar events, review factual records, and understand the evidence behind probable-cause and preliminary reports.
The investigative work and source records belong to the National Transportation Safety Board and the published investigation record. This site is not affiliated with or endorsed by the NTSB.
College Park, MD
BFR FLT, THE PLT OBTAINED FUEL SAMPLES THRU THE REMOTELY OPERATED GASCOLATOR, BUT DETECTED NO WATER. NO SAMPLES COULD BE DRAWN DIRECTLY FM THE WING OR FUSELAGE TANKS SINCE THEY HAD NO QUICK DRAINS INSTALLED. A PWR LOSS OCCURRED DRG TAKEOFF AT 50 TO 100 FT AGL. THE PLT SWITCHED FUEL TANKS (FROM L TO R MAIN) & ENGAGED THE BOOST PUMP. ENG PWR RETURNED AS THE ACFT STRUCK UTILITY LINES NEAR THE END OF THE RWY. THE ACFT THEN CRASHED & HIT A FENCE BFR COMING TO REST. A SIMILAR PWR LOSS OCCURRED APRX 3 WKS EARLIER. MAINT PSNL FOUND A LOOSE L TANK FUEL CAP WHICH COULD HAVE ALLOWED WATER TO LEAK INTO THIS TANK. A MECHANIC ADJUSTED THE FUEL CAP FOR A TIGHT FIT. THE ACFT WAS THEN FLOWN TWICE, PRIOR TO THE ACDNT, WITH NO EVIDENCE OF WATER IN THE FUEL OR OTHER DISCREPANCIES. HOWEVER, AFTER THE ACDNT, DIRECT ACCESS TO THE L MAIN TANK REVEALED THE PRESENCE OF WATER WHICH WAS COLORED PINK. PINK STAINS WERE ALSO PRESENT ON THE TANK WALL ABOVE THE AFT FUEL OUTLET PORT. THE OUTLET PORTS OF THE INTERCONNECTED MAIN TANK CELLS WERE 3/8 TO 1/2 INCH ABOVE THE TANK BOTTOMS.
BFR FLT, THE PLT OBTAINED FUEL SAMPLES THRU THE REMOTELY OPERATED GASCOLATOR, BUT DETECTED NO WATER. NO SAMPLES COULD BEDRAWN DIRECTLY FM THE WING OR FUSELAGE TANKS SINCE THEY HAD NO QUICK DRAINS INSTALLED. A PWR LOSS OCCURRED DRG TAKEOFF AT 50 TO 100 FT AGL. THE PLT SWITCHED FUEL TANKS (FROM L TO R MAIN) & ENGAGED THE BOOST PUMP. ENG PWR RETURNED AS THE ACFT STRUCK UTILITY LINES NEAR THE END OF THE RWY. THE ACFT THEN CRASHED & HIT A FENCE BFR COMING TO REST. A SIMILAR PWRLOSS OCCURRED APRX 3 WKS EARLIER. MAINT PSNL FOUND A LOOSE L TANK FUEL CAP WHICH COULD HAVE ALLOWED WATER TO LEAK INTO THIS TANK. A MECHANIC ADJUSTED THE FUEL CAP FOR A TIGHT FIT. THE ACFT WAS THEN FLOWN TWICE, PRIOR TO THE ACDNT, WITH NO EVIDENCE OF WATER IN THE FUEL OR OTHER DISCREPANCIES. HOWEVER, AFTER THE ACDNT, DIRECT ACCESS TO THE L MAIN TANK REVEALED THE PRESENCE OF WATER WHICH WAS COLORED PINK. PINK STAINS WERE ALSO PRESENT ON THE TANK WALL ABOVE THE AFT FUEL OUTLET PORT. THE OUTLET PORTS OF THE INTERCONNECTED MAIN TANK CELLS WERE 3/8 TO 1/2 INCH ABOVE THE TANK BOTTOMS.