Premium research interface

The modern interface for aviation safety intelligence.

Search investigations, review source evidence, monitor watched reports, and trace long-term patterns from one calm, data-first workspace.

63k+
Reports indexed
1940-2026
Coverage
Recent
Last data refresh
Featured Report

Loading…

Loading featured report…

Loading…
Open Report

Safety trends by operating rule

Track fatal and non-fatal accident patterns across Part 91, Part 135, and Part 121 operations.

Loading trend charts…

Browse the aviation graph

Move quickly by aircraft, airport, operator, and time with indexes built for research, not wandering.

Last Data Update

By Decade

By Month

Aircraft Manufacturer

More manufacturers

Airports

More airports

Operators

More operators

About

Aviation safety reports, made easier to study

NTSB Reports is an independent research and search tool for public aviation accident and incident records. It brings NTSB aviation reports, structured fields, docket files, extracted figures, photos, videos, and update history into one searchable interface.

The goal is practical safety education: make it faster to find relevant investigations, compare similar events, review factual records, and understand the evidence behind probable-cause and preliminary reports.

The investigative work and source records belong to the National Transportation Safety Board and the published investigation record. This site is not affiliated with or endorsed by the NTSB.

FAQs

NTSB Report

August 7, 2005 · Forbes Rutan Long EZE · N16WF

Albuquerque, NM

Overview

Report Status
Final with probable cause
Event Type
Accident
Date
August 7, 2005
Injury Outcomes
No injuries (1 uninjured)
Location
Albuquerque, NM
Aircraft
Forbes Rutan Long EZE
Tail Number
N16WF
Injuries
None
Aircraft Damage
Substantial
NTSB Number
DEN05LA123

On final approach to the runway, the pilot lowered the landing gear and visually inspected it through the sight glass to make sure it was down and locked. About 20 seconds later, there was a sudden and total electrical failure and the engine lost power. The pilot switched from the MAIN battery to the AUX battery in an attempt to restore electrical and engine power, but left it selected for only about 2 to 3 seconds. He then switched back to the MAIN battery and concentrated on the emergency forced landing. He could not recall if the propeller was windmilling at the time (a windmilling propeller would be necessary to start the engine using AUX battery power). The pilot made a forced landing on an access road and collided with a wall causing substantial damage. The airplane was equipped with a dual electronic ignition system, not magnetos. A constant source of electrical power was required for ignition. In the event of an electrical power loss, the engine would lose power. An FAA avionics inspector said the 5-amp main fuse had opened, probably due to a shorted wire inside the master relay, resulting in an over-current condition. This caused the master relay to de-energize and cut power to the bus. The alternator, which was tested to 10.5 volt output, has a nominal output of 13.8 volts. Minimal output to charge the battery is 12.5 volts. The FAA inspector's statement noted that the cockpit-mounted master switch activated the positive side of the master relay solenoid. Standard industry practice was to wire the positive side of the master relay to the unfused input from the battery, and then switch the negative side using the master switch. Some commercially available solenoids have the positive terminal wired to the battery input.

NTSB Probable Cause

a total electrical failure due to a short in the master relay, causing the main fuse to open. Contributing factors included an inadequate electrical design by the airplane's builder, a low-output alternator, a cement wall, and unsuitable terrain on which to make a forced landing.

Full Narrative

On August 7, 2005, approximately 1110 mountain daylight time, a Forbes' Rutan Long EZE, N16WF, piloted by a commercial pilot, was substantially damaged during a forced landing at Albuquerque International Sunport (ABQ), Albuquerque, New Mexico. Visual meteorological conditions prevailed at the time of the accident. The personal cross-country flight was being conducted under Title 14 Code of Federal Regulations Part 91, and a VFR flight plan had been filed. The pilot was not injured. The flight originated at Henderson Executive Airport (HND), Las Vegas, Nevada, approximately 0720 Pacific daylight time. According to the pilot, the airplane was serviced with 24 gallons of 100LL fuel, for a total of 45 gallons, before departing Las Vegas. He said the planned flight would consume approximately 26 gallons of fuel. He departed HND approximately 0720 and climbed to his VFR cruising altitude of 9,500 feet msl. Approximately 8 miles from ABQ, he began a descent to traffic pattern altitude. Approximately 3 miles from ABQ, he slowed from 140 knots to less than 100 knots in order to complete the BEFORE LANDING checklist and lower the landing gear. When the airplane was on a 1 mile final approach to runway 08, he lowered the landing gear and visually inspected it through the sight glass to make sure it was down and locked. About 20 seconds later, there was a sudden and total electrical failure and the engine lost power. The pilot switched from the MAIN battery to the AUX battery in an attempt to restore electrical and engine power, but left it selected for only about 2 to 3 seconds. He then switched back to the MAIN battery and concentrated on the emergency forced landing. He could not recall if the propeller was windmilling at the time (a windmilling propeller would be necessary to start the engine using AUX battery power). Concerned that he might hit a fence at the approach end of the runway, the pilot elected to land on a nearby access road. After touching down, the left wing struck a cement retaining wall. The airplane pivoted to the left and the main landing was gear torn off. The airplane then collided with the curb and gutter. Postaccident inspection revealed the nose gear structural spars were buckled, the bottom fuselage skin and winglets were scraped and ground down, and the fuselage was buckled. The airplane was equipped with a dual electronic ignition system, not magnetos. A constant source of electrical power was required for ignition. In the event of an electrical power loss, the engine would lose power. According to an FAA avionics inspector who examined the electrical system, the 5-amp main fuse had opened, probably due to a shorted wire inside the master relay, resulting in an over-current condition. This caused the master relay to de-energize, and cut power to the bus. The alternator, which tested to 10.5 volt output, has a nominal output of 13.8 volts. Minimal output to charge the battery is 12.5 volts. The FAA inspector's statement noted that the cockpit-mounted master switch activated the positive side of the master relay solenoid. Standard industry practice was to wire the positive side of the master relay to the unfused input from the battery, and then switch the negative side using the master switch. Some commercially available solenoids internally wire the positive terminal to the battery input.

Flight

Event TypeAccident
Event Time11:10 MDT
Nearest AirportAlbuquerque Intl. Sunport (0nm)
Runway8
Runway Length13793 ft
Runway Width150 ft
Flight Plan FiledVFR
Flight Plan ActivatedYes
Aircraft FireNo
Aircraft ExplosionNo

Aircraft

AircraftForbes Rutan Long EZE
Tail NumberN16WF
Aircraft CategoryAir
DamageSubstantial
Operating RulePart 91
Engines1
Engine TypeReciprocating
Engine DetailsLycoming · O-320-B2C · Reciprocating · 160

People & Injuries

Injury SummaryNo injuries (1 uninjured)
Fatal0
Serious0
Minor0
Uninjured1
Total1
Crew 1Age 42 · First Class · None

Conditions

ConditionsVMC
LightDaylight
WindCalm
Visibility10 sm
CeilingBroken clouds 10000 ft
Temperature / Dew Point57
Altimeter30.28 inHg
Observation Time16:56
Weather SourceWFAC

Appendix: Source Data