Premium research interface

The modern interface for aviation safety intelligence.

Search investigations, review source evidence, monitor watched reports, and trace long-term patterns from one calm, data-first workspace.

63k+
Reports indexed
1940-2026
Coverage
Recent
Last data refresh
Featured Report

Loading…

Loading featured report…

Loading…
Open Report

Safety trends by operating rule

Track fatal and non-fatal accident patterns across Part 91, Part 135, and Part 121 operations.

Loading trend charts…

Browse the aviation graph

Move quickly by aircraft, airport, operator, and time with indexes built for research, not wandering.

Last Data Update

By Decade

By Month

Aircraft Manufacturer

More manufacturers

Airports

More airports

Operators

More operators

About

Aviation safety reports, made easier to study

NTSB Reports is an independent research and search tool for public aviation accident and incident records. It brings NTSB aviation reports, structured fields, docket files, extracted figures, photos, videos, and update history into one searchable interface.

The goal is practical safety education: make it faster to find relevant investigations, compare similar events, review factual records, and understand the evidence behind probable-cause and preliminary reports.

The investigative work and source records belong to the National Transportation Safety Board and the published investigation record. This site is not affiliated with or endorsed by the NTSB.

FAQs

NTSB Report

December 4, 2010 · Eurocopter Deutschland Gmbh Mbb-Bk 117 C-1 · N271NE

Boston, MA

Overview

Report Status
Final with probable cause
Event Type
Incident
Date
December 4, 2010
Injury Outcomes
No injuries (4 uninjured)
Location
Boston, MA
Aircraft
Eurocopter Deutschland Gmbh Mbb-Bk 117 C-1
Tail Number
N271NE
Operator
Era Med
Injuries
None
Aircraft Damage
Minor
NTSB Number
ERA11IA091

During the air ambulance flight, the helicopter was on final approach to land when smoke and flames were observed emanating from the suction control mounted on the left side of the cabin. The fire was subsequently extinguished, and the pilot landed the helicopter without further incident. Postincident examination revealed fire damage on the face of an overhead medical cabinet that was part of a medical interior installed about 7.5 years prior to the incident per a supplemental type certificate. A sheathed wiring bundle for a 120-volt alternating current power outlet mounted in the aft end of the cabinet displayed chafing damage and arcing consistent with rubbing on the metal housing for the vacuum control switch. The wiring was installed without adequate clearance or support to prevent it from chafing on the switch housing. The helicopter was maintained under an approved inspection program; however, review of the instructions for continued airworthiness associated with the medical cabinet installation did not reveal any required inspections of the associated wiring harnesses for general condition or chafing.

NTSB Probable Cause

Improper installation of wiring associated with a medical cabinet interior, which resulted in chafing and a subsequent in-flight fire. Contributing to the incident was inadequate maintenance procedures for continued airworthiness.

Full Narrative

On December 4, 2010, about 0900 eastern standard time, a Eurocopter Deutschland GMBH, MBB-BK117-C1, N271NE, sustained minor damage when it experienced an in-flight electrical fire, while on approach to the Brigham & Women's Hospital Heliport (MA39), Boston, Massachusetts. The helicopter was owned by New England Life Flight, doing business as Boston MedFlight, and operated by ERA Med LLC, as an air ambulance flight conducted under the provisions of 14 Code of Federal Regulations Part 135. The airline transport pilot, flight nurse, flight paramedic, and patient were not injured. Visual meteorological conditions prevailed and a company flight plan had been filed for the flight that departed from Oak Bluffs, Massachusetts. According to the flight nurse, the helicopter was on final approach to land, when she noticed "a smell" followed by smoke and flames emanating from the suction control mounted on the left side of the cabin. She notified the pilot and discharged a fire extinguisher, which extinguished the fire. The pilot landed the helicopter without further incident. He subsequently noted obvious fire damage on the left cabin wall near the suction device control switch and the liquid oxygen gauge. Post incident inspection by a Federal Aviation Administration (FAA) inspector revealed fire damage on the face of the overhead medical cabinet around the vacuum control switch. The cabinet was part of a medical interior that was installed per a supplemental type certificate (STC) during May 2003, and housed a vacuum regulator, vacuum pump switch, liquid oxygen quantity indicator and 120-volt alternating current (AC) electrical outlets. A sheathed wiring bundle for the 120-volt AC power outlet mounted in the aft end of the cabinet displayed chafing damage and arching consistent with rubbing on the metal housing for the vacuum control switch. In addition, an approximate 2-inch portion of composite material, which surrounded the switch, was consumed by fire. Additional examination was performed by an FAA inspector, who reported that the wiring was installed without adequate clearance or support to prevent it from chafing on the switch housing. The electrical power to the outlets was supplied by a KGS Electronics SPS-1607A medical inverter system, which was installed per an STC during June 2003. Review of the instructions for continued airworthiness associated with the medical cabinet installation did not reveal any required inspections of the associated wiring harnesses for general condition or chafing. The helicopter was maintained under an FAA approved inspection program and had been operated for approximately 254 hours since its most recent 300 hour/12 month inspection, which was performed on August 12, 2010. Item 24 on the inspection checklist included: "Visually inspect inverter and mounting for damage, security and electrical connections" and "Test medical inverter for proper operation," with a reference to the KGS-SPS-1607A Removal/Installation Manual. Review of the KGS-SPS-1607A Removal/Installation Manual revealed instructions for removal and installation. Under instructions for maintenance, the manual stated "No regular periodic maintenance is required for this product. Service is required only when a malfunction is detected. Maintenance consists of removal and replacement." An FAA check of service difficulty reports for the BK117 did not reveal any previous instances of fires associated with the medical cabinet installation. FAA Advisory Circular AC65-15A, Airframe and Powerplant Mechanics Airframe Handbook, Chapter 11, Aircraft Electrical Systems, Protection Against Chafing, stated in part: "Wires and wire groups should be protected against chafing or abrasion in those locations where contact with sharp surfaces or other wires would damage the insulation. Damage to the insulation can cause short circuits, malfunction, or inadvertent operation of equipment…."

Flight

Event TypeIncident
Event Time09:00 EST
Nearest AirportBrigham & Women'S Hospital (0nm)
Flight Plan FiledCvfr
Flight Plan ActivatedYes
Aircraft FireIflt
Aircraft ExplosionNo

Aircraft

AircraftEurocopter Deutschland Gmbh Mbb-Bk 117 C-1
Tail NumberN271NE
Aircraft CategoryHeli
DamageMinor
OperatorEra Med
Operating RulePart 135
Engines2
Engine TypeTurboshaft
Engine DetailsTurbomeca · Ariel 1E2 · Turboshaft · 738 | Turbomeca · Ariel 1E2 · Turboshaft · 738
Seats7

People & Injuries

Injury SummaryNo injuries (4 uninjured)
Fatal0
Serious0
Minor0
Uninjured4
Total4
Crew 1Age 35 · First Class · None

Conditions

ConditionsVMC
LightDaylight
Wind300° @ 17 kt
Visibility10 sm
CeilingNone
Temperature / Dew Point36 C / 19 C
Altimeter29.65 inHg
Observation Time13:54
Weather SourceWFAC

Appendix: Source Data